FILTRATION SYSTEMS, INC.
TUBULAR MEMBRANE SPECIFICATIONS
Nomenclature Description
|
Example: Part Number S22-PV-70K (C)
|
S =
|
S refers to single tube, one inch diameter
|
22 =
|
Active membrane ft2. Ex. 22 equates to 2.2 ft2
|
PV =
|
Polymer Type (PV-PVDF, PE-PolyEtherSulfone)
|
70K =
|
Nominal Molecular Weight Cutoff
|
(C) =
|
CPVC Housing
|
|
|
Maximum Feed Pressure:
|
80 PSI
|
Burst Pressure:
|
200 PSI
|
Minimum Exit Pressure:
|
15 PSI
|
Pressure Drop Per Tube (Delta)
|
4 PSI (@20GPM 5 tube flow rate)
5 PSI (@30GPM 10 tube )
9 PSI (@40GPM 10 tube )
12 PSI (@50GPM 10 tube )
|
Maximum Temperature:
|
110o F PVC, 140o F - CPVC
|
Maximum Flow Rate:
|
50 GPM
|
Minimum Flow Rate:
|
20 GPM
|
Maximum pH Exposure:
|
2-11 pH
|
Maximum FOG Concentration:
|
50%
|
Maximum TSS Concentration:
|
80%
|
Prefiltration Requirement:
|
3,500 micron or smaller
|
Inside Diameter:
|
.998
|
Outside Diameter:
|
1.315
|
Membrane Length:
|
113
|
Permeate Port Size:
|
25 (Threaded)
|
End Fitting Size:
|
1.25 x 11.5TPI
|