| The Filtration Systems
tubular
ultrafilter consists of a PVC
housing and a PVDF membrane
tube.
The feed solution must be
compatible with both
components.
Listed below is the chemical
compatibility of the membrane
tube.
Under normal operating conditions the tubular ultrafilter
will operate at a pH of 2-11 and a temperature of 40-120F.
Acceptable Chemical List
The following chemicals have no significant impact on membrane
properties.
- q Aromatic hydrocarbons
- q Organic salts
- q Alcohols
- q Organic Acids
- q Ethers
- q Cellosolves
- q Alkali
- q Salts
- q Buffers
- q NaOCl < 200 PPM
- q H202 < 0.5%
- q Phenols
- q Inorganic Acids
- q Olive oil
Unacceptable Chemical List
The following chemicals will damage or dissolve the membrane.
- q Aprotic solvents
- q Ketones
- q Esters
- q Chlorinated Solvents
- q Aldehydes
- q Silcones
- q Amine
|